Next-Gen EnerShed Achieves UL 1741 Recognition, Enabling Q3 Commercial Shipments

Three-Phase Inverter

Hypernova-H Series

Delivering 98% efficiency in an industry-leading compact footprint, the Hypernova-H Series three-phase central inverter family provides reliable, code-compliant backup power and features OSHPD Special Seismic Certification preapproval for use in California healthcare facilities. Available from 5.0 to 50.0 kVA, it combines rapid transfer, flexible communication options and robust diagnostics for automated testing and monitoring. OSHPD SSC Preapproval Number: OSP-0895.

Power Capacity: 5.0kVA | 7.5kVA | 10.0kVA | 12.5kVA | 16.7kVA | 25.0kVA | 33.2kVA | 37.5kVA | 50.0kVA

Efficiency: 98% Efficient Typical

Runtime: 90 Minute Standard | Configurable (Contact Factory)

Transfer Time: No Break 2ms Transfer Time

Standard Diagnostics: Automatic Event, Test, and Alarm Log

Optional Diagnostics: Status Monitoring | Summary Form C Contacts | Summary Alarm | Output Trip Alarms | Remote Panels

Communications: Standard: RS-232 Port | Optional: BACnet, BACnet IP, Modbus TCP/IP, Modbus RTU, IoT Inverter Connect

Standard Features: Withstand Seismic Rating Based on Shaker Table Testing | PWM/IGBT Technology and Micro-Controller | Internal Maintenance Bypass | User Programmable with Password Protection | Input Circuit Breaker (65 KAIC Rating) | NEMA Type 1 Cabinet | Space-Saving Design | Low Audible Noise (45 dBA @1m) | Forced Air Cooling Only During Emergency Operation (No Filters Required)

Optional Features: External Maintenance Bypass | Output Circuit Breakers | Fast Charge | Seismic Mounting

Input Voltage: 120/208 or 277/480 VAC | 3-Phase 4-Wire Plus Ground | Custom Available (Contact Factory)

Output Voltage: 120/208 or 277/480 VAC | 3-Phase 4-Wire Plus Ground | Custom Available (Contact Factory)

Output Load Power Factor: 0.5 Lag to 0.5 Lead

Output Voltage Distortion: Less Than 3% THD for Linear Loads

Compatibility: Lighting Loads | Motor Loads

Inverter Operating Temp: 32°F to 104°F (0°C to 40°C)

Battery Operating Temp: 68°F to 86°F (20°C to 30°C)

Optional Service & Support: Factory Startup & Training | Extended Maintenance Plan | Extended Warranty

Cabinet Size (HxWxD"): 5.0-10kVA: Electronics 47x24x25; Batteries 62x17.5x25 | 12.5-16.7kVA: Electronics 47x30x25; Batteries 77x22.75x25 | 25-33.2kVA: Electronics 72x37.5x25; Batteries 77x45.5x25 | 37.5-50kVA: Electronics 72x37.5x25; Batteries 77x68.25x25

OSHPD-Rated
BAA Compliant
BABA Compliant
TAA
UL 924
NFPA 101